Arc suppression
Arc suppression is the reduction of the electric arc energy that occurs when current-carrying contacts are opened and closed. An electric arc is a man-made, continuous arc-discharge consisting of highly energized electrons and ions supported by an electric current of at least 100mA; not to be confused with an electric spark. Source: e01 Encyclopedia. Licence: CC BY-SA 4.0.
Arc suppression is the reduction of the electric arc energy that occurs when current-carrying contacts are opened and closed. An electric arc is a man-made, continuous arc-discharge consisting of highly energized electrons and ions supported by an electric current of at least 100mA; not to be confused with an electric spark. ==Uses== There are several possible areas of use of arc suppression methods, among them metal film deposition and sputtering, electrostatic processes where electrical arcs are not desired (such as powder painting, air purification, and contact current arc suppression. In industrial, military and consumer electronic design, the latter method generally applies to devices such as electromechanical power switches, relays and contactors. In this context, arc suppression is contact protection. ==Effectiveness== The efficacy of an arc suppression solution for contact protection can be assessed using the Contact Arc Suppression Factor ("CASF") to compare the calculated arc energy of the unsuppressed arc with that of the suppressed arc: CASF = W (arc) / W (arclet) Where W (arc) = Unsuppressed arc energy and W (arclet) = Suppressed arc energy. The unsuppressed and suppressed arc energy must be obtained graphically from oscilloscope measurements. The unsuppressed and suppressed arc energy is expressed in Watt seconds [Ws] or Joules [J]. The resulting Contact Arc Suppression Factor [CASF] is dimensionless. W (arc) = V (arc) × I (arc) × T (arc) Where V (arc) : Arc burn voltage, I (arc) : Arc burn current, is approximately I (load) , where I (load) may be in the range from a few Ampere [A] to kilo Ampere [kA]; and T (arc) : Arc burn duration, can be on the order of microseconds [μs] to seconds [s]. W (arclet) = V (arclet) × I (arclet) × T (arclet) Where V (arclet) : Arc ignition voltage, depending on the contact metal. E.g. about 12V for silver indium tin oxide; I (arclet) : Arclet current, is approximately I (load) and may be in the range from a few Ampere [A] to kilo Ampere [kA]; and T (arclet) : Arclet burn duration, is on the order of a few microseconds [μs]. Electrical arcing across the contacts of an electromechanical relay may be effectively measured using an oscilloscope connected to a differential voltage probe across the relay contacts and a high speed current probe to measure the current through the contacts during operation under load. Alternatively, the electrical arc may also be visually observed on an electromechanical power switch, relay and contactor, with visible contacts, while the contacts are opening and closing under load. ==Common devices== Common devices that may be reasonably effective arc suppressors in applications operating below 2 Amperes include capacitors, snubbers, diodes, Zener diodes, varistors, and transient voltage suppressors. Contact arc suppression solutions that are considered effective in applications operating at more than 2 Amperes include: Electronic Power Contact Arc Suppressor Solid state relays are not electromechanical, have no contacts, and, thus, do not create electrical arcs. Hybrid power relays Hybrid power contactors ==Specialized devices== The circuit diagram is part of an issued patent for an electronic power contact arc suppressor intended to protect the contacts of electrical relays or contactors. It suppresses arcs by providing an alternate path around contacts as they open or close. Some contact arc suppressors operate connected solely across the protected contact, while other contact arc suppressors are also connected to the coil of the contactor to provide the suppressor with additional input about contact operation. ==Benefits of arc suppression== Arc suppression techniques can produce a number of benefits: Minimized contact damage from arcing and therefore reduced maintenance, repair and replacement frequency. Increased contact reliability. Reduced heat generation resulting in less heat management measures such as venting and fans. Reduced ozone and pollutant emissions. Reduced electromagnetic interference (EMI) from arcs - a common source of radiated EMI. ==See also== Contact protection ==References== ==Further reading== Relays - Frequently Asked Questions Arc suppression articles on Institute of Electrical and Electronics Engineers website
Cite this
"Arc suppression". 1789943542. e01 Encyclopedia. CC BY-SA 4.0. https://en.wikipedia.org/w/index.php?oldid=1375936881 JSON record · API collection · BibTeX · RIS · CSL-JSON · citation policy