CAN FD
CAN FD (Controller Area Network Flexible Data-Rate) is a data-communication protocol used for broadcasting sensor data and control information on 2 wire interconnections between different parts of electronic instrumentation and control system. This protocol is used in modern high performance vehicles. CAN FD is an extension to the original CAN bus protocol that was specified in ISO 11898-1. CAN FD is the second generation of CAN protocol developed by Bosch. The basic idea to overclock part of the frame and to oversize the payload dates back to 1999. Developed in 2011 and released in 2012 by Bosch, CAN FD was developed to meet the need to increase the data transfer rate up to 5 times faster... Source: e01 Encyclopedia. Licence: CC BY-SA 4.0.
CAN FD (Controller Area Network Flexible Data-Rate) is a data-communication protocol used for broadcasting sensor data and control information on 2 wire interconnections between different parts of electronic instrumentation and control system. This protocol is used in modern high performance vehicles. CAN FD is an extension to the original CAN bus protocol that was specified in ISO 11898-1. CAN FD is the second generation of CAN protocol developed by Bosch. The basic idea to overclock part of the frame and to oversize the payload dates back to 1999. Developed in 2011 and released in 2012 by Bosch, CAN FD was developed to meet the need to increase the data transfer rate up to 5 times faster and with larger frame/message sizes for use in modern automotive Electronic Control Units. As in the classical CAN, CAN FD protocol is designed to reliably transmit and receive sensor data, control commands and to detect data errors between electronic sensor devices, controllers and microcontrollers. Although CAN FD was primarily designed for use in high performance vehicle ECUs, the pervasiveness of classical CAN in the different industries will lead into inclusion of this improved data-communication protocol in a variety of other applications as well, such as in electronic systems used in robotics, defense, industrial automation, underwater vehicles, medical equipment, avionics, down-hole drilling sensors, etc. β = τ/ω (β = Busload), (τ = time of slow bits plus faster bits), ω (time in seconds of measurement). τ = Ts + Tf CAN-FD protocol defines five different error detection mechanisms: Two of them work at the bit level, and the other three at the message level. They are: - (1) Bit Monitoring, - (2) Bit Stuffing, - (3) Frame Check, - (4) Acknowledgement Check and - (5) Cyclic Redundancy Check. There are two options of CRC which should be denoted as for CRC length of 17 (Data Length 0-16 bytes) or CRC length of 21 bits (Data Length 17–64) bytes. Where the transmission time of the (fixed-size) header is given by: \textstyle T_s = \left(\frac{\left(\text{SOF}+\text{ID}+r1+\text{IDE}+\text{EDL}+r0+\frac{\text{BRS}}{2}+\frac{\text{CRCdel}}{2}\right) \cdot 1.2}{t_x}\right) +\frac{\text{ACK}+\text{DEL}+\text{EOF}+\text{IFS}}{t_x} The fields are explained in the table below. Here 1.2 is taken to be the factor of the worst case bit stuffing, which means the computation shall be increased by 25%. It is considered BRS and CRCdel divided by 2, because they are exactly in the shift of bit rate transition. The transmission time of the payload is calculated as: \textstyle T_f = \frac{\left(\left(D_f+\text{ESI}+\text{DLC}+\frac{\text{BRS}}{2}+\frac{\text{CRCdel}}{2}\right) \cdot 1.2\right) + \text{CRC} + \text{SB}}{t_Y} Here SB signifies the stuffing bits (5 bits for packets smaller than 6 bytes and 6 bits for packets bigger than 6 bytes). CRC is also size-dependent, set to 17 bits for packets smaller than 6 bytes and to 21 for larger packets. Df represents the CAN-FD payload size which may be 0 to 8, 12, 16, 20, 24, 32, 48, 64 Bytes. t_X is the transmission bandwidth for the message header (up to 1 Mbit/s). CAN FD also has decreased the number of undetected errors through increases in the performance of the CRC-algorithm. In addition, CAN FD is compatible with existing CAN 2.0 networks, allowing the new protocol to function on the same network as classical CAN. CAN FD bit rate can be up to 8 Mbit/s with the right CAN SIC (Signal Improvement Capability) Transceiver and so up to 8 times faster than classical CAN with 1 Mbit/s data phase. Due to higher communication speed, CAN FD constraints are tougher in terms of line parasitic capacitance. Therefore, all components on the line have seen their "capacitance" budget reduced compared to regular CAN bus. That is the reason why semiconductor suppliers have released new components approved by car makers. This approval reflects the need for interoperability between all CAN FD systems. Indeed, selected ESD protection components are compatible with all transceivers (CAN or CAN FD) and withstand ISO7637-3. Despite a higher stand-off voltage≤ (37 V), devices for truck applications must also comply with the low capacitance requirement (3.5 pF). ==References==
Cite this
"CAN FD". 1787714295. e01 Encyclopedia. CC BY-SA 4.0. https://en.wikipedia.org/w/index.php?oldid=1371393265 JSON record · API collection · BibTeX · RIS · CSL-JSON · citation policy