EMI 2001
Studio C in July 1991. The last programme in the world to use EMI 2001s to record images was EastEnders The EMI 2001 broadcast studio camera was an early, very successful British made Plumbicon studio camera that included the lens within the body of the camera. Four 30 mm tubes allowed one tube to be dedicated solely to producing a relatively high resolution monochrome signal, with the other three tubes each providing red, green and blue signals. Even though semiconductors were used in most of the camera, the highly sensitive head amplifiers still used thermionic valves in the first generation of the design. Source: e01 Encyclopedia. Licence: CC BY-SA 4.0.
Studio C in July 1991. The last programme in the world to use EMI 2001s to record images was EastEnders]] The EMI 2001 broadcast studio camera was an early, very successful British made Plumbicon studio camera that included the lens within the body of the camera. Four 30 mm tubes allowed one tube to be dedicated solely to producing a relatively high resolution monochrome signal, with the other three tubes each providing red, green and blue signals. Even though semiconductors were used in most of the camera, the highly sensitive head amplifiers still used thermionic valves in the first generation of the design. ===Generating the image=== The composite signals of the NTSC, PAL and SECAM systems are made up of a wideband luminance signal and two narrow-band colour difference signals containing B-Y and R-Y. If a band-limited version of the signal from the luminance tube is used to derive the colour difference signals, without modification, then colour errors would occur. This is because the luminance characteristic expected by the colour processing must be made up in a particular way, using specific proportions of red, green and blue, whereas the signal from the luminance tube has a more general monochromatic characteristic akin to that from a conventional black and white camera. In addition, the application of gamma correction to the signals further complicates the situation (display tubes have, approximately, a square law characteristic with γ ≈ 2.2). As shown below, it is beneficial, but not sufficient, to shape the luminance response to simulate that of the NTSC (PAL or SECAM) luminance characteristic (by, for example, placing an optical filter in front of the luminance tube to pass light with the required luminosity function, or by a special dichroic surface which reflects light to the luminance tube with the required luminosity function ). For a basic 3-colour system the wideband luminance signal (Y'), for NTSC, PAL and SECAM, is given by: Y' = 0.3R^{\frac{1}{\gamma}} + 0.59G^{\frac{1}{\gamma}} + 0.11B^{\frac{1}{\gamma}} In the case of a separate luminance tube, with appropriate spectral shaping, the output signal (Y) is given by: Y = 0.3R + 0.59G + 0.11B which when gamma-corrected gives: Y^{\frac{1}{\gamma}} = (0.3R +0.59G + 0.11B)^{\frac{1}{\gamma}} Y^{\frac{1}{\gamma}} does not equal Y' except when R = G = B, which corresponds to neutral (grey) tones. When deriving the two narrowband colour difference signals containing R N and B N , a bandlimited version of the luminance signal (y') is required, namely: y' = 0.3R_N^{\frac{1}{\gamma}} + 0.59G_N^{\frac{1}{\gamma}} + 0.11B_N^{\frac{1}{\gamma}} but the band limited signal from the luminance tube is: y^{\frac{1}{\gamma}} = (0.3R_N +0.59G_N + 0.11B_N)^{\frac{1}{\gamma}} As before, y^{\frac{1}{\gamma}} does not equal y' . If the gamma corrected luminance signal y^{\frac{1}{\gamma}} is simply used instead of y' then colour errors result which can be appreciable for saturated colours. In the EMI 2001 a process known as Delta-L Correction is used to overcome this problem. A band-limited luminance difference correction signal, ΔL is formed, where: \Delta L = y^{\frac{1}{\gamma}}- y' This narrowband signal is used to correct the wideband luminance channel at low frequencies, so the monochrome signal transmitted becomes: Y^{\frac{1}{\gamma}} - \Delta L = Y^{\frac{1}{\gamma}} - (y^{\frac{1}{\gamma}}- y') With this corrected luminance signal, the correct colour rendition is obtained, whilst still retaining the sharp luminance detail of a 4-tube camera. The narrowband R, G and B signals are gamma corrected and applied to a suitable matrixing circuit, to derive the correction. With grey scale scenes y^{\frac{1}{\gamma}} = y' and the signal reverts to that of the luminance tube only. \phi (f) = -6.36 \times 10^{-5} \times f where is the frequency in Hz and (f) is in degrees. At low frequencies, the propagation delays of the two filters are both the same (177 ns, approximately). ==Operational history== First produced in 1966, by the early 1970s almost all of BBC Television's studios and many outside broadcast (OB) units were equipped with the 2001. Several ITV companies purchased or leased the camera including Thames Television, Yorkshire Television, Associated Television/Central Independent Television, Granada, HTV, Anglia, London Weekend Television and Independent Television News. Independent outfits such as the early cable television stations Rediffusion Cablevision, Sheffield Cablevision and the educational television arm of the Inner London Education Authority also purchased the camera. When sold abroad, the EMI 2001 was carried under the Thomson SA brand – hence "Thomson TH.T 2001". How this came about is unknown as EMI and Thomson SA did not have business links. The Thomson 2001s, like the EMIs, also used Plumbicons; however, due to a brochure which was printed in French, it was presumed that they used Vidicon tubes. But, apart from the silver viewfinder squares (instead of white) and the brand name change on the front and sides, the cameras were the same. In the United States, the cameras were marketed by International Video Corporation as the IVC/EMI 2001-B (four tubes), with another version, the IVC/EMI 2001-C, consisting of three tubes. Only one U.S. station is known to have purchased the 2001: WSNS-TV in Chicago, in the early years of its operation. Although there was no predicted lifespan for the camera, the heavy hot-running four-tube design was considered somewhat outdated even when it was new, which contributed to the camera's near-total failure to sell to broadcasters outside the UK. Furthermore, when EMI closed-down the Broadcast Equipment Division in the late 1970s, studios were deprived of technical and spares support for their cameras. Consequently, several ITV companies began replacing them in the late-1970s with the last commercial operators (Yorkshire & Central) both phasing them out in 1986 (in the main, Central had disposed of them in 1984, however they were used for continuity and presentation from its Birmingham operation until 1986). However the BBC kept a number of such cameras in operation at BBC Television Centre, its various regional outposts and its BBC Elstree Centre for some years afterwards, the last being at Elstree until July 1991; they were kept running by "cannibalising" identical cameras left behind by Central when the BBC purchased Elstree from it in 1984 as well as BBC EMI 2001s disposed of in previous years. ==References== ==External links== Demonstration of EMI 2001 'lining up process by ex BBC OB operators Ex BBC OB camera operators discuss their experience working with the EMI 2001 BBC Tech Ops History Site Museum of the Broadcast Television Camera The website of Martin Kempton on London television studios contains much on the industries use of various cameras over the decades, including the EMI 2001.
Cite this
"EMI 2001". 1762615157. e01 Encyclopedia. CC BY-SA 4.0. https://en.wikipedia.org/w/index.php?oldid=1321086668 JSON record · API collection · BibTeX · RIS · CSL-JSON · citation policy