K-edge
In X-ray absorption spectroscopy, the K-edge is a sudden increase in x-ray absorption occurring when the energy of the X-rays is just above the binding energy of the innermost electron shell of the atoms interacting with the photons. The term is based on X-ray notation, where the innermost electron shell is known as the K-shell. Physically, this sudden increase in attenuation is caused by the photoelectric absorption of the photons. For this interaction to occur, the photons must have more energy than the binding energy of the K-shell electrons (K-edge). A photon having an energy just above the binding energy of the electron is therefore more likely to be absorbed than a photon having an... Source: e01 Encyclopedia. Licence: CC BY-SA 4.0.
In X-ray absorption spectroscopy, the K-edge is a sudden increase in x-ray absorption occurring when the energy of the X-rays is just above the binding energy of the innermost electron shell of the atoms interacting with the photons. The term is based on X-ray notation, where the innermost electron shell is known as the K-shell. Physically, this sudden increase in attenuation is caused by the photoelectric absorption of the photons. For this interaction to occur, the photons must have more energy than the binding energy of the K-shell electrons (K-edge). A photon having an energy just above the binding energy of the electron is therefore more likely to be absorbed than a photon having an energy just below this binding energy or significantly above it. The energies near the K-edge are also objects of study, and provide other information. ==Use== The two radiocontrast agents iodine and barium have ideal K-shell binding energies for absorption of X-rays: 33.2 keV and 37.4 keV respectively, which is close to the mean energy of most diagnostic X-ray beams. Similar sudden increases in attenuation may also be found for other inner shells than the K shell; the general term for the phenomenon is absorption edge. Dual-energy computed tomography techniques take advantage of the increased attenuation of iodinated radiocontrast at lower tube energies to heighten the degree of contrast between iodinated radiocontrast and other high attenuation biological material present in the body such as blood and hemorrhage. ==Metal K-edge== Metal K-edge spectroscopy is a spectroscopic technique used to study the electronic structures of transition metal atoms and complexes. This method measures X-ray absorption caused by the excitation of a 1s electron to valence bound states localized on the metal, which creates a characteristic absorption peak called the K-edge. The K-edge can be divided into the pre-edge region (comprising the pre-edge and rising edge transitions) and the near-edge region (comprising the intense edge transition and ~150 eV above it). ==Ligand K-edge== Ligand K-edge spectroscopy is a spectroscopic technique used to study the electronic structures of metal-ligand complexes. This method measures X-ray absorption caused by the excitation of ligand 1s electrons to unfilled p orbitals (principal quantum number n \leq 4 ) and continuum states, which creates a characteristic absorption feature called the K-edge. D_0(L \ 1s \rightarrow \psi^*) = const \ \vert \langle L \ 1s \vert \mathbf{r} \vert \psi^* \rangle \vert^2 D_0 = \frac{\alpha^2 h}{3n}I_s where n is the number of absorbing ligand atoms, h is the number of holes, and I s is the transition dipole integral which can be determined experimentally. Therefore, by measuring the intensity of pre-edges, it is possible to experimentally determine the amount of ligand character in a molecular orbital.
Cite this
"K-edge". 1762188060. e01 Encyclopedia. CC BY-SA 4.0. https://en.wikipedia.org/w/index.php?oldid=1320259450 JSON record · API collection · BibTeX · RIS · CSL-JSON · citation policy