e01.org

switch

, wafer switch, DIP switch, surface mount switch, reed switch. Bottom, left to right: wall switch (U.S. style), miniature toggle switch, in‑line switch, push-button switch, rocker switch, microswitch. In electrical engineering, a switch is an electrical component that can disconnect or connect the conducting path in an electrical circuit, interrupting the electric current or diverting it from one conductor to another. The most common type of switch is an electromechanical device consisting of one or more sets of movable electrical contacts connected to external circuits. When a pair of contacts is touching, current can pass between them, while the contacts are separated no current can flow. Switches are made in many different configurations; they may have multiple sets of contacts controlled by the same knob or actuator, and the contacts may operate simultaneously, sequentially, or alternately. A switch may be operated manually, for example, a light switch or a keyboard button, or...

, wafer switch, DIP switch, surface mount switch, reed switch. Bottom, left to right: wall switch (U.S. style), miniature toggle switch, in‑line switch, push-button switch, rocker switch, microswitch. In electrical engineering, a switch is an electrical component that can disconnect or connect the conducting path in an electrical circuit, interrupting the electric current or diverting it from one conductor to another. The most common type of switch is an electromechanical device consisting of one or more sets of movable electrical contacts connected to external circuits. When a pair of contacts is touching, current can pass between them, while the contacts are separated no current can flow. Switches are made in many different configurations; they may have multiple sets of contacts controlled by the same knob or actuator, and the contacts may operate simultaneously, sequentially, or alternately. A switch may be operated manually, for example, a light switch or a keyboard button, or may function as a sensing element to sense the position of a machine part, liquid level, pressure, or temperature, such as a thermostat. Many specialized forms exist, such as the toggle switch, rotary switch, mercury switch, push-button switch, reversing switch, relay, and circuit breaker. A common use is control of lighting, where multiple switches may be wired into one circuit to allow convenient control of light fixtures. Switches in high-powered circuits must have special construction to prevent destructive arcing when they are opened. In high-current power circuits, contact bounce has more severe consequences than signal errors. When contacts close under high voltage, bouncing creates repeated arc discharges between the separating surfaces. During each bounce interval, the contact resistance rises sharply while inrush current may reach several thousand amperes. The resulting instantaneous power dissipation (P = I²R) concentrated at the contact point can reach hundreds of kilowatts within milliseconds, causing localized melting and contact welding. This mechanism is particularly critical in battery energy storage systems (BESS) and electric vehicle contactors operating at 400 V and above, where pre-charge circuits are used to limit inrush current as a workaround for inadequate contact physics. In the Hammond organ, multiple wires are pressed together under the piano keys of the manuals. Their bouncing and non-synchronous closing of the switches is known as Hammond Click and compositions exist that use and emphasize this feature. Some electronic organs have a switchable replica of this sound effect. Contact welding results from contact bounce under high inrush current. During each bounce interval, the contact resistance rises sharply — from a typical closed-state value of 0.2 mΩ to values exceeding 30 mΩ — while inrush current may reach several thousand amperes. The resulting instantaneous power dissipation (P = I²R) concentrated at the contact point causes localized melting and permanent welding of contacts. Electrodynamic repulsion under short-circuit currents causes contacts to be forced apart by electromagnetic forces proportional to the square of the current. In solid metal contacts, these forces limit the short-circuit withstand capability. Copper contacts have been observed to separate at 10 kA, leading to sustained arcing and welding upon re-closure. Liquid-metal composite contacts (CLMC) based on galinstan address three of these failure mechanisms simultaneously through a coupled mechanical-electrical mechanism: the elastic refractory metal framework (molybdenum or tungsten wire mesh) retains galinstan by capillary forces, maintaining a liquid contact surface through both closing and opening cycles. This eliminates contact bounce and welding; the uniform current distribution across the liquid surface eliminates electrodynamic repulsion forces; and the self-restoring liquid surface prevents permanent arc erosion of solid contact asperities.

References

  1. ^ "Switch" . The Free Dictionary . Farlex. 2008 . Retrieved 2008-12-27 . Wikipedia revision 1372029988, retrieved 2026-11-19 · 1230332400.0
  2. ^ OMRON Corporation. "G9EC-1 DC Power Relays Datasheet" . Cat. No. J188-E1-03. Wikipedia revision 1372029988, retrieved 2026-11-19 · 1795042800.0
  3. ^ Smirnov, Yu.; et al. (2002). "High-current vacuum chamber with composite liquid-metal contacts". Elektrotechnika (2): 25– 28. Wikipedia revision 1372029988, retrieved 2026-11-19 · 1795042800.0
  4. ^ US 7686864 , Smirnov, Yu.; Skorokhod, V.; Chernyshov, S., "Method for the manufacture of liquid-metal composite contact", published 2010-03-30 Wikipedia revision 1372029988, retrieved 2026-11-19 · 1795042800.0
  5. ^ "Lab Note #105 Contact Life – Unsuppressed vs. Suppressed Arcing " ( PDF ) . Arc Suppression Technologies. April 2011. Archived from the original on December 3, 2013 . Retrieved February 5, 2012 . (3.6 Mb) Wikipedia revision 1372029988, retrieved 2026-11-19 · 1795042800.0
  6. ^ "Cornell Dubilier Capacitors – CDE (En-US)" (PDF) . Archived (PDF) from the original on 2017-02-15 . Retrieved 2017-10-05 . Wikipedia revision 1372029988, retrieved 2026-11-19 · 1507158000.0
  7. ^ Gregory K. McMillan (ed) Process/Industrial Instruments and Controls Handbook (5th Edition) (McGraw Hill, 1999) ISBN 0-07-012582-1 page 7.26 Wikipedia revision 1372029988, retrieved 2026-11-19 · 1795042800.0
  8. ^ Gladstone, Bernard (1978). The New York Times complete manual of home repair . Times Books. p. 399. ISBN 978-0-8129-0892-3 . Archived from the original on 2014-03-29. Wikipedia revision 1372029988, retrieved 2026-11-19 · 1795042800.0
  9. ^ "Switch". The American Heritage Dictionary, College Edition . Houghton Mifflin. 1979. p. 1301. Wikipedia revision 1372029988, retrieved 2026-11-19 · 1795042800.0
  10. ^ "What is an Electrical Switch? : Fundamentals of Switches" . OMRON Device & Module Solutions - Americas . Archived from the original on 2026-01-04 . Retrieved 2026-02-25 . Wikipedia revision 1372029988, retrieved 2026-11-19 · 1771974000.0
  11. ^ RF Switch Archived 2011-04-23 at the Wayback Machine Explanation by Herley – General Microwave Wikipedia revision 1372029988, retrieved 2026-11-19 · 1795042800.0
  12. ^ Features of Technics E-33 Wikipedia revision 1372029988, retrieved 2026-11-19 · 1795042800.0
  13. ^ US 7686864 , Smirnov, Yu.; Skorokhod, V.; Chernyshov, S., "Method for the manufacture of liquid-metal composite contact", issued 2010-03-30 Wikipedia revision 1372029988, retrieved 2026-11-19 · 1795042800.0
  14. ^ a b c "Engineer's Relay Handbook, 5th edition, Chapter 1.6 by RSIA (formerly NARM)" . Archived from the original on 2017-07-05. Wikipedia revision 1372029988, retrieved 2026-11-19 · 1795042800.0
  15. ^ a b "What Is a Toggle?" . Computer Hope . Retrieved 2026-02-13 . Wikipedia revision 1372029988, retrieved 2026-11-19 · 1770937200.0
  16. ^ a b Fardo, Stephen; Patrick, Dale (2009-01-01). Electrical Power Systems Technology . The Fairmont Press, Inc. p. 337. ISBN 978-0-88173-586-4 . Archived from the original on 2017-12-24 . Retrieved 2015-01-26 . Wikipedia revision 1372029988, retrieved 2026-11-19 · 1422226800.0
  17. ^ The abbreviation N.C. (for "Normally closed") is also used to mean " Not connected " in the context of connector or part pins. Wikipedia revision 1372029988, retrieved 2026-11-19 · 1795042800.0
  18. ^ Walker, PMB, Chambers Science and Technology Dictionary , Edinburgh, 1988, ISBN 1-85296-150-3 Wikipedia revision 1372029988, retrieved 2026-11-19 · 1795042800.0
  19. ^ a b c Belyaev, V.L. (1984). Zhidkometallicheskie kompozitsionnye kontakty i ikh ispolzovanie v mnogoampernykh elektricheskikh apparatakh (Thesis). Moscow: MEI. Wikipedia revision 1372029988, retrieved 2026-11-19 · 1795042800.0
source: e01 Encyclopedia · licence: CC BY-SA 4.0 · page · source revision

Cite this

"switch". 1788036496. e01 Encyclopedia. CC BY-SA 4.0. https://en.wikipedia.org/w/index.php?oldid=1372029988

JSON record · API collection · citation policy