e01.org

Y-factor

The Y-factor method is a widely used technique for measuring the gain and noise temperature of an amplifier. It is based on the Johnson–Nyquist noise of a resistor at two different, known temperatures. Consider a microwave amplifier with a 50-ohm impedance with a 50-ohm resistor connected to the amplifier input. If the resistor is at a physical temperature T R , then the Johnson–Nyquist noise power coupled to the amplifier input is P J = k B T R B, where k B is the Boltzmann constant, and B is the bandwidth. The noise power at the output of the amplifier (i.e. the noise power coupled to an impedance-matched load that is connected to the amplifier output) is P out = Gk B (T R + T amp )B, where G is the amplifier power gain, and T amp is the amplifier noise temperature. In the Y-factor technique, P out is measured for two different, known values of T R . P out is then converted to an effective temperature T out (in units of kelvin) by dividing by k B and the measurement bandwidth B....

The Y-factor method is a widely used technique for measuring the gain and noise temperature of an amplifier. It is based on the Johnson–Nyquist noise of a resistor at two different, known temperatures. Consider a microwave amplifier with a 50-ohm impedance with a 50-ohm resistor connected to the amplifier input. If the resistor is at a physical temperature T R , then the Johnson–Nyquist noise power coupled to the amplifier input is P J = k B T R B, where k B is the Boltzmann constant, and B is the bandwidth. The noise power at the output of the amplifier (i.e. the noise power coupled to an impedance-matched load that is connected to the amplifier output) is P out = Gk B (T R + T amp )B, where G is the amplifier power gain, and T amp is the amplifier noise temperature. In the Y-factor technique, P out is measured for two different, known values of T R . P out is then converted to an effective temperature T out (in units of kelvin) by dividing by k B and the measurement bandwidth B. The two values of T out are then plotted as a function of T R (also in units of kelvin), and a line is fit to these points (see figure). The slope of this line is equal to the amplifier power gain. The x intercept of the line is equal to the negative of the amplifier noise temperature −T amp in kelvins. The amplifier noise temperature can also be determined from the y intercept, which is equal to T amp multiplied by the gain.

source: e01 Encyclopedia · licence: CC BY-SA 4.0 · page · source revision

Cite this

"Y-factor". 1755019456. e01 Encyclopedia. CC BY-SA 4.0. https://en.wikipedia.org/w/index.php?oldid=1305556210

JSON record · API collection · BibTeX · RIS · CSL-JSON · citation policy

Save to pass ·